INNOVATION AUTOMATIC CO.,LTD

FOCUS ON PRODUCTION OF AUTOMATIC WEIGHING SYSTEM!

Manufacturer from China
Active Member
5 Years
Home / Products / Packing Machine Accessories /

PW15AH Single Point Load Cell For Waterproof Check Weigher / Filling Machine

Contact Now
INNOVATION AUTOMATIC CO.,LTD
City:hangzhou
Province/State:zhejiang
Country/Region:china
Contact Person:Kenna QIU
Contact Now

PW15AH Single Point Load Cell For Waterproof Check Weigher / Filling Machine

Ask Latest Price
Brand Name :innovation
Model Number :IN-PW15AH
Place of Origin :China
MOQ :10pcs
Payment Terms :D/P, L/C, T/T, Western Union
Supply Ability :50pcs per month
Accuracy class :C3
Sensitivity (Cn) :2.0±0.2 mV/V
Protection class according to EN 60 529 (IEC 529) :IP68
Type :PW15AH
Accuracy class1) :C3 Multi Range (MR)
Number of load cell intervals (nLC) :3000
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description
IN-PW15AH Single Point Load Cell For WATERPROOF Check Weigher/ Filling Machine
IN-PW15AH Single point load cell
Application: WATERPROOF bench scale,
check weigher, filling machine, etc.
Special features
- Hermetically sealed(IP68; IP69K)
- highest reliability
- Reduced minimum load cell verification
interval(V min) for multi range applications
- Interchangeable to products of many
manufacturers
- Stainless steel
- 6-wire-technology
- Integrated connection for protective cable conduit systems

PW15AH Single Point Load Cell For Waterproof Check Weigher / Filling Machine

PW15AH Single Point Load Cell For Waterproof Check Weigher / Filling Machine

Type PW15AH
Accuracy class1) C3 Multi Range (MR)
Number of load cell intervals (nLC) 3000
Maximum capacity (Emax)2)) kg 10 20 50 100
Minimum LC verification
interval
g 1 2 5 10
Temperature effect on zero balance % v. Cn / 10 K ±0.0140 ±0.0140 ±0.0140 ±0.0140
Max. platform size mm 500 x 400
Sensitivity (Cn) mV/V 2.0±0.2
Zero balance 0±0.1
Temperature effect on sensitivity (TKC)3)
Temperature range
+20 ... +40℃ [+68 ...
+104℉]
−10 ... +20℃ [+14 ...
+68℉]
% v. Cn / 10 K ±0.0175
±0.0117
Hysteresis error (dhy)3) % of Cn ±0.0166
Non-linearity (dlin)3) ±0.0166
Minimum dead load output
return (DR)
±0.0166
Off center load error4) ±0.0233
Input resistance (RLC) Ω 300 ... 500
Output resistance (R0) 330 ... 500
Reference excitation voltage
(Uref)
V 5
Nominal range of excitation
voltage (BU)
1...12
Max. excitation voltage 15
Insulation resistance (Ris) at
100 VDC
> 1
Nominal temp. range (BT) °C [°F] −10 ... +40 [+14 ... +104]
Service temp. range (Btu) −10 ... +50 [+14 ... +122]
Storage temp. range (Btl) −25 ... +70 [−13 ... +158]
at max. eccentricity mm 160
Lateral load limit (Elq), static % of
Emax
300
Breaking load (Ed) 300
Protection class according to
EN 60 529 (IEC 529)
IP68(test conditions 100 h at 1m water column);IP69K(water at high presure,steam jet
cleaning)
Material: Measuring element Coating
Cable sheath
C1.4545
Silicone rubber
PVC
Inquiry Cart 0